The problem that the factory encountered in the first few days was the easily deformed neck welded flange. A customer ordered 10 pieces of neck welded flange plates. Production is produced. But I got off the lathe and loaded it onto the truck. Measure the size again, there is a problem with *.
The product requested by the customer also does not have a waterline or bolt holes* It is a tablet product. The company has communicated with the customer, and the customer is also very headache about this matter.
Some areas are larger in size, while others are smaller. The problem * is that these neck welded flanges are too thin. If this problem is transported in this way, it cannot be avoided.
**Finally, everyone came up with a solution. When welding the steel bars on the lathe, the size of the neck welding flange was fixed. With the fixation of the steel bars, the size * remained unchanged. However, the customer welded the neck welding flange plate transported to the site to the equipment before removing the steel bars. And polish the position of the welded steel bars.
This solves the problem of deformation of the neck welded flange during transportation.